L-PAK 150/250 StandardEN
8
5.1.1 L-PAK O (O mode)
The unit is in O mode, which is also the unit’s start menu. The unit can also go into O
mode if something is wrong, such as if an alarm is acvated. The pump motor is o, there is
no vacuum, the FCV is closed, and the unit cannot be acvated by a pilot signal.
ESC OK
Nederman
Hi Vacuum Unit
L-PAK
OFF
Time To Service
2000 hours
TimeToService: The amount of me unl next scheduled service. The
default seng is 2000 hours. See Secon
6.2.2. H-Meter 1.
5.1.2 L-PAK Standby (Standby mode)
The unit is in Standby mode and is ready. The pump motor is o, there is no vacuum, the
FCV is closed, and the unit is waing for a pilot signal to go into Running mode.
ESC OK
Hi Vacuum Unit
Standby
Waing For
Pilot Signal
Mo 15:33
2018-01-22
5.1.3 Running (Running mode)
The unit in Running mode. The pump motor is on and the unit generates a vacuum. The
FCV is closed.
ESC OK
Hi Vacuum Unit
Running
Time 05:33 Min
DIRTm 00:00 s
DIRTm: The amount of me before the unit goes into Idling mode. The
default is 10 seconds. See also Secon
6.2.4. DIR_Time.
OTTmr: If the Overme mer has been acvated, OTTmr shows the
elapsed me since the overme mer started.
Time: The number of minutes the fan engine has been running since the
last start.
5.1.4 Idling (Idling mode)
The unit in Idling mode. The pump motor is on, there is no vacuum, and the FCV is open.
The unit goes into Idling mode when there has been no pilot signal for the me set in DIR_
Time, see Secon
6.2.4. DIR_Time.
ESC OK
Hi Vacuum Unit
IDLING
Time To
StandBy
05:33m
Time to Standby: The amount of me unl the unit goes into Standby
mode. The default seng is 12 minutes. See Secon
6.2.3. SSR_Time.