L-PAK 150/250 Standard
9
EN
5.1.5 Filter Cleaning
The unit is cleaning its lter.
ESC OK
Filter
Cleanining
Cycles 1
Elapsed 0
Clean 00:00 s
Charge 00:00 s
Cycles: How many cleaning pulses will be carried out.
Elapsed: How many cleaning pulses are made.
Clean: Remaining me for cleaning pulse.
Charge: Remaining vacuum build me; the me unl cleaning pulse is
acvated.
5.1.6 Status report
1.
ESC OK
Thu 10:45
2018-02-01
ESC OK
ESC + C 9/9
ESC OK
Status Report 2
CASAlarm 1
ESC OK
Status Report 1
Sn: 2180523-0-EN
Starts 0
FLT M-Prot 0
FanTempHi 0
CleanePulse 0
ESC OK
NEDERMAN
Hi Vacum Unit
L-PAK Standard
OFF
TimeTo Service
2000 Hours
Press the down arrow once to show the me and date screen.
2. Press the right arrow unl the arrow screen appears.
1) Press Escape
and the up arrow at the same me to show the Status Report
screen.
2) Press Escape
and the up arrow at the same me to show the next Status
Report screen.
Sn Soware number– Revision- Language.
Starts The number of motor starts.
FLT M-Prot Number of mes motor overload protector has been acvated.
FanTempHi Number of mes Hi Temp Fan, thermostat has acvated fan Cooling.
CleanePulse Number of cleaning pulses by the cleaning valve.
CASAlarm How many mes Compressed Air Switch has alerted for low pressure.
5.2 Warning messages
If a warning is acvated, there is a problem that needs to be corrected, but the unit
connues to work.
When a warning is acvated, Output Q4 and White lamp buon “Filter Cleaning/ Test
start” ash with intervals, 1 second On/3 second O.
If the ush valve funcon is chosen, it disconnects Output Q4 as a warning/Alarm signal
output. See secon
6.5. Warning-Alarm output Q4.