5.7 Adjustingtheregenerationfrequency(modelswithsofteneronly)
5.8 Memorisationprocedure
Toaccesstheprogrammingmenu,proceedasfollows:
1) switchtheapplianceoffbypressingtheOnOffkey
2) Holddowntheandkeyssimultaneouslyfor6seconds;H0appearsonthedisplay
3) Usethe keytomodifytheparameter;H0,H1,H2,H3,H4,H5andH0willappearonthedisplay
incyclicsequence
4) PresstheOnOffkeytoconfirmthechangeandquitprogrammingmode.
With values over 60°dF an external water treatment device must be used and the
regenerationfrequencymustbesetatH00
5.9 Tableofparameters
Thistableshowstherelationshipbetweentheintakewaterhardnessandthequantitytheresinsare
abletotreat;regenerationisrequiredoncetheappliancehasperformedthesetnumberofcycles.
Regenerationcycleduration:12minutes.
Hardness(°dHGerman
degrees)
Hardness(°dFFrench
degrees)
Settinglevel
Resindurationin
washcycles
Regenerationoff Regenerationoff H00 Functionoff
8.5 15 H01 94washcycles
11 20 H02 83washcycles
17 30 H03 53washcycles
22,5 40 H04default 33washcycles
28 50 H05 27washcycles
33.5 60 H06 20washcycles