6 MALFUNCTIONS SHOWN ON THE DISPLAY (FOR
THE TECHNICIAN)
Thewarewasherisabletoidentifyanumberofmalfunctionsandshowthemonthedisplay.
Iftheproblempersistsafterthewarewasherhasbeenswitchedoffandbackon,proceedasdescribed
below:
E.1 Boilertemperatureprobemalfunction
Boilertemperatureprobedisconnectedornot
working
E.2 Tanktemperatureprobemalfunction
Tanktemperatureprobedisconnectedornot
working
E.3 Waterintakemalfunction Waterintakenotcompletedinthemaximumtime
allowed
Checkdynamicpressureinintakesystem,clean
waterintakefilter.
Iftheproblempersists:
‐tankpressureswitchhasfailed(continuousempty
reading)
‐leakfrompipeconnectedtoairtrap
‐drainsiphonblocked‐thetankisemptydueto
siphoningwhenthedrainpumpisnotrunning
alsocontrols:
iftankandboilerpressureswitchproperly
iftherubberpipesareconnectedcorrectly
iftheairtrapisclogged/dirty
iftherinsepumprunningcorrectly
E.4 Boileroverheating. Reduceboilertemperature<80°.
Circuitboardrelayfailed,checkcircuitboardand
inspectboilerheatingelementfordamage
E.5 Tankoverheating Reduceboilertemperature<58°.
Circuitboardrelayfailed,checkcircuitboardand
inspecttankheatingelementfordamage