2 TECHNICAL DATA

Supplyvoltage V 400V3N~
Supplyvoltage V
Frequency Hz 50
Max.powerabsorptionat400V3N~ kW 5,2
Max.powerabsorptionat230V1N~ kW 3.7
Boilerheatingelementpowerat400V3N~ kW 4.5
Boilerheatingelementpowerat230V1N~ kW 1,5/3
Tankheatingelementpower kW 0,8
Waterintakepressure kPa(bar) 100600(1÷6)
Waterintaketemperature °C 15°C60°C
Intakewaterhardness(modelswithsoftener) °f 15°f60°f
Rinsecyclewaterconsumption l 3.2
Boilercapacity l 6
Tankcapacity l 11
Standardcycledurationwithintakewaterat50°C S 90/120/180
Noiselevel dB(A) <70
Degreeofprotection IPX 4
Netweight Kg 63/60
Powersupplycabletype HAR H07RNF
Fuse A 4
400V3N~ 230V1N~
C SC
C=PowerSupplyCableS=masterswitch
‐‐‐‐ ‐‐‐‐ 2,2kW ‐‐‐‐
‐‐‐‐ ‐‐‐‐ 3.7kW ‐‐‐‐
5x2.5 16°3P+N 5,2kW 5x2.5
