EasyManua.ls Logo

Nemtek Taut Wire Node - Hardware Setup; Technical Specifications - Node Board; Technical Specifications - Recommended Power Supply

Nemtek Taut Wire Node
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Hardware Setup
5
4.1 Technical Specifications - Node Board
Parameter Value
Board Power Supply Requirement (No Taut Wire Sensors) 10-15Vdc/300mA
Board Power Supply Requirement (62 Taut Wire Sensors) 10-15Vdc/830mA
Relay Output Maximum Rating 48Vdc/1.3A
Digital Output Channel Maximum Rating* (per channel) 38Vdc/60mA**
Digital Output +V Out Maximum Rating 500mA
Taut Wire Vout Maximum Rating (per channel) 350mA***
Digital Input Maximum Rating* -5Vdc to 15Vdc****
Operating Temperature -20 to 50 °C
Maximum Taut Wire Sensors per channel 31
Number of Separate Sensor Channels 2
Number of Relay Outputs***** 2 (One per channel)
Number of Digital Outputs 4
Number of Digital Inputs 4
Network Communication RJ45 10/100Mbps
Ethernet
*Digital inputs and outputs can only be configured with network commands
** Outputs are open collector (potential free)
***Limited with resettable fuse
****Inputs have internal pull-up resistors to 5V
*****Relay outputs can be configured to be triggered with network commands
4.2 Technical Specifications - Recommended Power Supply
with battery
Parameter Value
Main Power Supply* 230Vac/50Hz +-10%/25VA
Output Maximum Rating 13.8Vdc/2A**
Battery Specification 12V/7Ah Rechargeable Sealed Lead-Acid
*Only for power supply with included mains transformer
**Limited by resettable fuse