EasyManuals Logo

NetApp DS4246 User Manual

NetApp DS4246
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Steps
1. Verify that your system configuration is Multi-Path HA or Multi-Path (single-controller-
dual-path):
sysconfig
For multipath HA configurations operating in 7-Mode, you can run the command from either
controller. For clustered systems, you run this command from the nodeshell.
It might take up to a minute for the system to complete discovery.
The configuration is listed in the System Storage Configuration field.
Note: For FAS22xx and FAS25xx systems with external storage, the output is displayed as
Mixed-Path HA for an HA pair, and Mixed-Path for a single-controller configuration.
This is because the internal storage is cabled differently than the external storage. For an
HA pair, the internal storage is cabled as single-path HA and the external storage is cabled
as multipath HA. For a single-controller configuration, the internal storage is cabled as
single-path and the external storage is cabled as dual-path (multipath).
Attention: If your non FAS22xx or FAS25xx
system is shown as something other than Multi-
Path HA or Multi-Path, you cannot continue
with this procedure. Your system must meet the
prerequisites stated in the "Before you begin"
section of this procedure.
2. Verify that no aggregates are on the disk drives in the disk shelves you are removing, by
completing the applicable substeps:
If your system is operating in...
Then...
7-Mode
a. Enter the following command:
aggr status -r
If you have traditional volumes, you enter the vol status -r command.
For multipath HA configurations, you can enter the command from the
console of either controller.
b. Check the output SHELF column to verify that the disk shelves from which
you have removed aggregates do not appear.
Clustered Data ONTAP
a. Enter the following command from the clustershell:
storage disk show -shelf shelf_number -container-type !
spare
For multipath HA configurations, you can enter the command from the
console of either controller.
b. Check the output to verify that all the disk drives in the disk shelves you are
removing are spares or failed.
If all disk drives are spares, the output message is There are no
entries matching your query. If any disk drives are failed, output
contains a line item for each failed disk drive and shows the disk drive as
broken.
Attention: If any disk drives in the disk shelves you
are removing are anything other than spares or
failed, you cannot continue with this procedure.
DS4243, DS2246, DS4486, and DS4246 Installation and Service Guide 24
Hot-removing disk shelves or stacks in systems running Data ONTAP 8.2.1 or later

Table of Contents

Other manuals for NetApp DS4246

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp DS4246 and is the answer not in the manual?

NetApp DS4246 Specifications

General IconGeneral
Data transfer rate6 Gbit/s
Storage drive size3.5 \
Storage drive interfaceSerial Attached SCSI (SAS)
Storage drives installedYes
Installed storage drive typeHDD
Supported storage drive typesHDD & SSD
Total installed storage capacity40.8 TB
Maximum supported storage capacity- TB
Number of storage drives installed24
Chassis typeRack (4U)
Product colorBlack
Device classLarge Enterprise Business
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Number of power supply units2
Operating altitude0 - 3045 m
Non-operating altitude-305 - 12192 m
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Storage relative humidity (H-H)10 - 95 %
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth610 mm
Width483 mm
Height178 mm