9. Reestablish the stack by connecting the disconnected disk shelves, or by connecting the
unconnected disk shelf to the controllers.
Note: Wait at least 10 seconds before connecting the port. The SAS cable connectors are
keyed; when oriented correctly into a SAS port, the connector clicks into place and the
disk shelf SAS port LNK LED illuminates green. For disk shelves, you insert a SAS cable
connector with the pull tab oriented down (on the underside of the connector).
10. Turn on the power to the storage system.
11. Reboot the storage system.
12. If applicable, return the failed part to NetApp, as described in the RMA instructions that are
shipped with the kit.
Contact technical support at
NetApp Support
, 888-463-8277 (North America),
00-800-44-638277 (Europe), or +800-800-80-800 (Asia/Pacific) if you need the RMA
number or additional help with the replacement procedure.
DS4243, DS2246, DS4486, and DS4246 Installation and Service Guide 32
Removing disk shelves in systems running Data ONTAP 8.2 or earlier

Table of Contents