::> system controller slot module insert -node node1 -slot 6-1
Warning: NVMe module in slot 6-1 of the node localhost will be powered
on and initialized.
Do you want to continue? (y|n): `y`
The module has been successfully powered on, initialized and placed into
service.
7.
Verify the slot status using the
system controller slot module show command.
Make sure that command output reports status for the as
powered-on and ready for operation.
8. Verify that the replacement caching module is online and recognized, and then visually confirm that the
amber attention LED is not lit:
sysconfig -av slot_number
If you replace the caching module with a caching module from a different vendor, the new
vendor name is displayed in the command output.
9. Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the Part
Return & Replacements
page for further information.
Chassis
Replace the chassis - FAS9500
Before you begin
To replace the chassis, you must remove the power supplies, fans, controller modules,
I/O modules, DCPM modules, and USB LED module from the impaired chassis, remove
the impaired chassis from the equipment rack or system cabinet, install the replacement
chassis in its place, and then install the components into the replacement chassis.
All other components in the system must be functioning properly; if not, you must contact technical support.
About this task
• You can use this procedure with all versions of ONTAP supported by your system.
• This procedure is disruptive. For a two-node cluster, you will have a complete service outage and a partial
outage in a multi-node cluster.
Shutdown the impaired controller - FAS9500
You must shut down the controller or controller in the chassis prior to moving them to the new chassis.
About this task
• If you have a cluster with more than two controllers, it must be in quorum. If the cluster is not in quorum or
a healthy controller shows
false for eligibility and health, you must correct the issue before shutting down
the impaired controller; see the
Administration overview with the CLI.
• If AutoSupport is enabled, suppress automatic case creation by invoking an AutoSupport message:
723