(SVMs) on the formerly impaired site now active and serving data from the local disk
pools.
This task only applies to two-node MetroCluster configurations.
Steps
1.
Verify that all nodes are in the
enabled state: metrocluster node show
cluster_B::> metrocluster node show
DR Configuration DR
Group Cluster Node State Mirroring Mode
----- ------- -------------- -------------- ---------
--------------------
1 cluster_A
Ê controller_A_1 configured enabled heal roots
completed
Ê cluster_B
Ê controller_B_1 configured enabled waiting for
switchback recovery
2 entries were displayed.
2.
Verify that resynchronization is complete on all SVMs:
metrocluster vserver show
3. Verify that any automatic LIF migrations being performed by the healing operations were completed
successfully:
metrocluster check lif show
4.
Perform the switchback by using the
metrocluster switchback command from any node in the
surviving cluster.
5.
Verify that the switchback operation has completed:
metrocluster show
The switchback operation is still running when a cluster is in the waiting-for-switchback state:
cluster_B::> metrocluster show
Cluster Configuration State Mode
-------------------- ------------------- ---------
ÊLocal: cluster_B configured switchover
Remote: cluster_A configured waiting-for-switchback
The switchback operation is complete when the clusters are in the normal state.:
88

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp FAS8200 and is the answer not in the manual?

NetApp FAS8200 Specifications

General IconGeneral
ControllerDual
Maximum Drives1440
NVMe Flash CacheYes
Form Factor4U
Operating SystemONTAP
High AvailabilityYes
NVRAM32GB
Maximum Flash Cache12TB
Connectivity16Gb FC
Maximum Memory256GB
ProtocolsNFS, CIFS, iSCSI, FC
ProcessorIntel Xeon
Drive Types SupportedSAS, SSD
Data Protection FeaturesRAID-DP, RAID-TEC, SnapMirror, SnapVault

Related product manuals