41
Telnet protocol does not contain energy measurement data and counters. This protocol is
recommended to Outputs control only.
When the Telnet is enabled, other M2M protocols are disabled. After clicking Save changes, you will
be asked to confirm the deactivation of the other protocols.
Click Confirm to confirm the action or Cancel to return to the Telnet protocol configuration.
Start Telnet connection to a NETIO device IP address and its Telnet port
When the connection is established, the NETIO device returns the following response and is ready to
receive commands.
Telnet welcome message
100 HELLO 489F6C4F - KSHELL V2.1
Note: The Telnet connection is automatically terminated after 60 seconds of inactivity. It is possible
to use the noop command to keep the connection alive for the next 60 seconds.
Command set
login <username>
<password>
Log in a user.
Replace <username> and <password> by the
equvalent attributes defined in the Telnet
protocol configuration (Figure 28)
<password>
Example ā log in with username netio and
password netio:
login netio netio
Log out and terminate Telnet connection.
Keep the Telnet connection alive for the next
60 seconds.
No-operation