EasyManua.ls Logo

Newco FKP-4 - Troubleshooting Error Messages

Newco FKP-4
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
ERROR MESSAGES
Message - "CONTACT/SERVICE”
LWR/UPR THERM
THERMISTOR IS OPEN OR SHORTED-
REPLACE PN 151677
Message - "CONTACT/SERVICE”
OVERHEAT
RAPID TEMPERATURE RISE-HEATER ON WITH LOW
WATER LEVEL-CHECK FILL VALVE OR WATER SUPPLY
LINE
Message - "CONTACT/SERVICE”
TOP/BTM BREW MOTOR OPEN
BREW CHAMBER DRIVE MOTOR ERROR-CHECK FOR
JAM OR OBSTRUCTION IN BREW CHAMBER
Message - "CONTACT/SERVICE”
CHECK WATER
WATER NOT REACHING LEVEL PROBE-CHECK WATER
SUPPLY OR CHECK FOR WATER LEAK
Message - “CONTACT/SERVICE”
CHECK WATER
WATER NOT HEATED DURING TIMEOUT PERIOD-CHECK
HEATER RELAY PN 110958 OR HEATING ELEMENT PN
704166-10(1700W US) OR 704161-10 (1400W CANADA) OR
HI-LIMIT THERMOSTAT PN 111593