12
Set Temperature: In this entry the user may set the tank temperature in the range of
180 to 203 degrees Fahrenheit with the default at 200 degrees F. Pressing the green (+) and
(-) buttons will change the set point, incrementing or decrementing by one. Pressing the
Blue “Return” button will exit.
Set Energy Save Mode: This entry allows the user to select the Power Save mode.
Pressing the green (+) and (-) buttons will change the entry then press the Blue “Return”
button to exit.
Off Mode (default) –No Energy Save
Energy Save– Partial Power Save Mode. After
the user selected Idle Time is reached, the tank
temperature set point is reduced to 180 until a key is
pressed.
Full Energy Save – Full Power Save Mode. After
the user selected Idle Time is reached, the tank heater
is disabled until a key is pressed.
Set Idle Time: This entry sets the time the machine will operate normally until
the power save function is activated. The user can choose 1 through 4 hours in 1-hour
increments with the default set to 4 hours. As with most of the entries, pressing the
green (+) and (-) buttons will change the entry then press the Blue “Return” button to
exit.
Set Buzzer Volume: The range is from 0 to 100. The default is 20.