14
Recipe Settings: This entry takes the user into a
sub menu to program the parameters unique to each
recipe.
There are six entries in the RECIPE Parameters sub menu:
SET BREW VOLUME: This entry sets the volume in ounces for this key to dispense.
The Range is from 2.0 to 16 ounces with the default set to 7 ounces for small, 8ounces
for medium, and 9 ounces for large.
SET PRE-INFUSION VOLUME: This entry sets the volume in ounces of the pre-
infusion pulse of water. Range is 0 to 3.0
SET COFFEE PUMP SPEED: In this entry the user may set the dc pump strength in
the range of 10% to 100% with the default at 35. As with most of the entries, pressing the
green (+) and (-) buttons will change the entry then press the Blue “Return” button to exit.
(Note that high pump speed can negatively affect extraction and can be noisy)
SET AIR PUMP SPEED: In this entry the user may set the air pump strength in the
range of 30% to 100% with the default at 80. As with most of the entries, pressing the green
(+) and (-) buttons will change the entry then press the Blue “Return” button to exit.
SET AIR PUMP TIME: In this entry the user may set the air pump time in the range of 2 to
15 seconds with the default at 10. As with most of the entries, pressing the green (+) and
(-) buttons will change the entry then press the blue “Return” button to exit.
SET BREW PULSE TIME: This entry sets the brew time off in seconds for a 7-ounce cup
of coffee with on/off pulses. The range is from 0 to 30 seconds.
EXIT: Exit to Main Programming Menu.