Technical documentation
EVC 13Model
Yes No
Condensing boiler
Yes No
Low-temperature boiler
Yes No
B11 boiler
Yes No
Cogeneration space heater
Yes No
Combination heater
%36.6ƞ
s
Seasonal space heating energy efficiencykW9PratedRated heat output
For boiler space heaters and boiler combination heaters: Useful efficiencyFor boiler space heaters and boiler combination heaters: Useful heat output
%40ƞ
4
At rated heat output and high-temperature re-
gime
kW9P
4
At rated heat output and high-temperature re-
gime
%ƞ
1
At 30 % of rated heat output and low-temperat-
ure regime
kWP
1
At 30 % of rated heat output and low-temperat-
ure regime
Other itemsAuxiliary electricity consumption
kW0.15P
stby
Standby heat losskWelmaxAt full load
kWP
ign
Ignition burner power consumptionkWelminAt part load
kWh20,310Q
HE
Annual energy consumptionkW0.01P
SB
Standby mode
dB35L
WA
Sound power level, indoors
For combination heaters
%ƞ
wh
Water heating energy efficiencyDeclared load profile for water heating
kWhQ
fuel
Daily fuel consumptionkWhQ
elec
Daily energy consumption
GJAFCAnnual fuel consumptionkWhAECAnnual energy consumption
31EVC 13
English