Menu 1.3.1 heating
Increases or decreases in the accommodation temperature can be sched-
uled here for up to three time periods per day. If a room sensor is installed
and activated the desired room temperature (°C) is set during the time
period. Without an activated room sensor the desired change is set (of
setting in menu 1.1). One step is usually enough to change the room
temperature by one degree, but in some cases several steps may be re-
quired.
SCHEDULING HEATING 1.3.1
activated
schedule 2
system
schedule 3schedule 1
all
mon
tues
wed
thur
fri
sat
sun
21:30 - 06:00
20.5°
Time period AdjustingDay
Activated Schedule System
Conflict
Adjusting: How much the heating curve is to be offset in relation to menu
1.1 during scheduling is set here. If the rooms sensor is installed the desired
room temperature is set in °C.
Caution
Changes of temperature in accommodation take time. For example,
short time periods in combination with underfloor heating will not give
a noticeable difference in room temperature.