With low price mode of "SG Ready" the parallel offset of the indoor tem-
perature is increased by "+1". If a room sensor is installed and activated,
the desired room temperature increases by 1 °C.
With over capacity mode of "SG Ready" the parallel offset for the indoor
temperature is increased by"+2". If a room sensor is installed and activated,
the desired room temperature increases by 2 °C.
affect hot water
Here you set whether the temperature of the hot water should be affected
when activating "SG Ready".
With low price mode on "SG Ready" the stop temperature of the hot water
is set as high as possible at only compressor operation (immersion heater
not permitted).
With over capacity mode of "SG Ready" the hot water is set to "luxury"
(immersion heater permitted).
affect cooling (accessory required)
Here you set whether room temperature during cooling operation should
be affected when activating "SG Ready".
With low price mode of "SG Ready" and cooling operation the indoor
temperature is not affected.
With over capacity mode of "SG Ready" and cooling operation the parallel
offset for the indoor temperature is reduced by"-1". If a room sensor is
installed and activated, the desired room temperature decreases by 1 °C.
affect pool temperature (accessory is required)
Here you set whether pool temperature should be affected when activating
"SG Ready".
With low price mode on "SG Ready", the desired pool temperature (start
and stop temperature) is increased by 1 °C.
With over capacity mode of "SG Ready", the desired pool temperature
(start and stop temperature) is increased by 2 °C.
NOTE
The function must be connected and activated in your F1155.
61NIBE™ F1155Chapter 3 | F1155 at your service