F1355-28Model
0.48l/sNominal flow
75kPaMax external avail. pressure at nominal flow
0.65l/sFlow at P
designh
70kPaExternal available pressure at P
designh
see diagram°CMin/max HM-temp
Noise
47dB(A)
Sound power level (L
WA
) according to EN 12102 at 0/35
32dB(A)
Sound pressure level (L
PA
) calculated values according to EN ISO 11203
at 0/35 and 1 m range
Pipe connections
G50 (2" external) / G40 (1 1/2" internal)Brine diam. CU pipe
G50 (2" external) / G40 (1 1/2" internal)Heating medium diam. CU pipes
Compressor oil
POEOil type
1.45 / 1.9lVolume EP14 / EP15
Dimensions and weight
600mmWidth
620mmDepth
1,800mmHeight
1,950mmRequired ceiling height
5)
335kgWeight complete heat pump
125 / 130kgWeight only cooling module EP14 / EP15
065 436Part no., 3x400V
1)
Scale for the product’s efficiency class room heating: A++ to G.
2)
Scale for the system’s efficiency class room heating: A+++ to G. Reported efficiency for the system takes the product’s temperature regu-
lator into account.
4)
Max permitted impedance in the mains connection point in accordance with EN 61000-3-11. Start currents can cause short voltage dips that
may affect other equipment in unfavourable conditions. If the impedance in the mains connection point is higher than that stated, it is probable
that interference will occur. If the impedance in the mains connection point is higher than that stated, check with the power supplier before
purchasing the equipment.
5)
With feet removed, the height is approx. 1930 mm.
WORKING RANGE HEAT PUMP, COMPRESSOR OPERATION
The compressor provides a supply temperature up to 65 °C.
Cooling module EP15
Vattentemperatur
°C
Arbetsområde under 75% för F1155-1255 6kW,
för hela arbetsområdet 12 och 16 kW.
°C
Framledning
Returledning
0
-15 -10 -5 0 5 10 15 20 25 30 35
20
10
30
40
50
60
70
Köldbärare in, temperatur
0
-15 -10 -5 0 5 10 15 20 25 35
20
40
60
70
Vattentemperatur
(°C)
Köldbärare in
(°C)
30
Framledning
Returledning
50
30
10
Temperature, °C
Flow pipe
Return pipe
Incoming brine temp, °C
Cooling module EP14
Vattentemperatur
°C
Arbetsområde under 75% för F1155-1255 6kW,
för hela arbetsområdet 12 och 16 kW.
°C
Framledning
Returledning
0
-15 -10 -5 0 5 10 15 20 25 30 35
20
10
30
40
50
60
70
Köldbärare in, temperatur
Temperature, °C
Flow pipe
Return pipe
Incoming brine temp, °C
NIBE F1355Chapter 8 | Technical data42