EasyManua.ls Logo

Nibe F2015 - Technical Specifications

Nibe F2015
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
F2015-11F2015-8F2015-6Type
9.4/2.67.1/1.85.4/1.4(kW)Delivered/supplied power* at 2/35 °C **
11.1/2.68.2/1.96.3/1.4(kW)Delivered/supplied power* at 7/35 °C **
7.1/2.95.0/2.13.7/1.6(kW)Delivered/supplied power* at -7/45 °C **
8.8/3.16.4/2.14.9/1.6(kW)Delivered/supplied power* at 0/45 °C **
10.9/3.27.8/2.26.0/1.7(kW)Delivered/supplied power* at 7/45 °C **
7.1/3.24.9/2.33.6/1.7(kW)Delivered/supplied power* at -7/50 °C **
9.2/3.46.6/2.45.0/1.8(kW)Delivered/supplied power* at 2/50 °C **
10.8/3.67.6/2.45.9/1.8(kW)Delivered/supplied power* at 7/50 °C **
12.8/3.69.2/2.47.2/1.9(kW)Delivered/supplied power* at 15/50 °C **
5.3/2.83.7/2.02.6/1.5(kW)Delivered/supplied power* at -15/45 °C **
10.9/2.88.0/1.96.1/1.5(kW)Delivered/supplied power at 7/35 °C ***
3.954.154.21COP at 7/35 °C ***
271917(A)Starting current
221614(A)Motor protection setting
included as standardSoft-start relay
230 V 1AC 50HzOperating voltage
Scroll compressorCompressor
0.250.200.16(l/s)Nominal flow heating medium
2.21.51.3(kPa)Internal pressure drop at nominal flow
0.5/2.5(bar)Min-/max pressure heating medium side
1700/20001700/20001500(m
3
/h)Airflow
90/13090/13070(W)Nominal output, fan
252020(A)Fuse
IP 24Enclosure class
60(°C)Max outgoing heating medium temperature
2.12.11.9(kg)Refrigerant volume (R407C)
G1 28 mm)Connection heating medium male Ø
hot gas defrostingDefrosting system
29(bar)Cut-out value pressostat HP
0.3(bar)Cut-out value pressostat LP
-7(bar)Difference pressostat HP
+0.7(bar)Difference pressostat LP
1045(mm)Height with stand
1200(mm)Width
520(mm)Depth
132126120(kg)Weight
dark greyColour
-15/45 (-15/45)(°C)Lowest operational point, outdoor air/flow line
35/58(°C)Highest operational point, outdoor air/flow line
064 015064 014064 044Part No.
Compressor, fan and control. Flows according to EN 255.
Defrosting reduces the relationship between input/output
by about 10 %.
*
outside temperature/Flow temperature**
According to EN 14511***
33F2015
Miscellaneous
Technical specifications