Sound pressure levels
F2040 is usually placed next to a house wall, which
gives a directed sound distribution that should be
considered. Accordingly, you should always attempt
when positioning to choose the side that faces the least
sound sensitive neighbouring area.
The sound pressure levels are further affected by walls,
bricks, differences in ground level, etc and should
therefore only be seen as guide values.
F2040 adjusts the fan speed depending on the ambient
temperature and evaporation temperature.
F2040-16F2040-12F2040-8Air-water heat pump
615754L
W
(A)Sound power level* According to EN12102 at 7/45 (nominal)
474340dB(A)Sound pressure level at 2 m free standing.*
37.533.530.5dB(A)Sound pressure level at 6 m free standing.*
332926dB(A)Sound pressure level at 10 m free standing.*
* Free space.
45Chapter 11 | Technical dataNIBE™ F2040