Symbol key
MeaningSymbol
Shut-off valve
Non-return valve
Mixing valve
Shunt / shuttle valve
Safety valve
Temperature sensor
Circulation pump
Radiator system
Domestic hot water
Under floor heating systems
Cold and hot water
CONNECTING COLD AND HOT WATER
A mixer valve must also be installed, if the factory
setting for hot water is changed. National regulations
must be observed.
The setting for hot water is made in menu 5.1.1 (page
48).
XL4 XL3
Heating medium side
CONNECTING THE CLIMATE SYSTEM
A climate system is a system that regulates indoor
comfort with the help of the control system in F730 and
for example radiators, under floor heating/cooling, fan
coils etc.
When connecting to a system with thermostats on all
radiators, a relief valve must be fitted, or some of the
thermostats must be removed to ensure sufficient
flow.
XL2 XL1
NIBE F730Chapter 4 | Pipe and ventilation connections18