Transport
F730 is supplied in two sections and can be installed
separately or as one unit. The images in this manual
show F730 installed as one unit. For more information
see page 19.
F730 should be transported and stored vertically in a dry
place. However. the F730 may be carefully laid on its
back when being moved into a building. The centre of
gravity is in the upper part.
Assembly
• Position F730 on a fixed foundation that can take the
weight of the heat pump. Use the product's adjustable
feet to obtain a horizontal and stable set-up.
Because water comes from F730, the floor coating is
important. A waterproof floor or floor membrane is
recommended.
30 - 50 mm
30 - 50 mm
15 - 40 mm
• Install with its back to an outside wall, ideally in a room
where noise does not matter, in order to eliminate
noise problems. If this is not possible, avoid placing
it against a wall behind a bedroom or other room
where noise may be a problem.
• Wherever the unit is located, walls to sound sensitive
rooms should be fitted with sound insulation.
• Route pipes so they are not fixed to an internal wall
that backs on to a bedroom or living room.
• The heat pump's installation area should always have
a temperature of at least 10 °C and max 30 °C.
NIBE F730Chapter 2 | Delivery and handling8
2 Delivery and handling