TECHNICAL DOCUMENTATION
F730Model
Air-water
Exhaust-water
Brine-water
Water-water
Type of heat pump
Yes No
Low-temperature heat pump
Yes No
Integrated immersion heater for additional heat
Yes No
Heat pump combination heater
Average Cold Warm
Climate
Average (55 °C) Low (35 °C)
Temperature application
EN14825, EN14511, EN16147, EN12102Applied standards
%132ƞ
s
Seasonal space heating energy efficiencykW4,5PratedRated heat output
Declared coefficient of performance for space heating at part load and at outdoor
temperature Tj
Declared capacity for space heating at part load and at outdoor temperature Tj
-2.3COPdTj = -7 °CkW4.0PdhTj = -7 °C
-3.4COPdTj = +2 °CkW2.4PdhTj = +2 °C
-4.4COPdTj = +7 °CkW1.6PdhTj = +7 °C
-4.2COPdTj = +12 °CkW1.7PdhTj = +12 °C
-2.3COPdTj = bivkW4.0PdhTj = biv
-2.3COPdTj = TOLkW3.6PdhTj = TOL
-COPdTj = -15 °C (if TOL < -20 °C)kWPdhTj = -15 °C (if TOL < -20 °C)
°C-10TOLMin. outdoor air temperature°C-7T
biv
Bivalent temperature
-COPcycCycling interval efficiencykWPcychCycling interval capacity
°C60WTOLMax supply temperature-0.97CdhDegradation coefficient
Additional heatPower consumption in modes other than active mode
kW0.9PsupRated heat outputkW0.003P
OFF
Off mode
kW0.02P
TO
Thermostat-off mode
ElectricType of energy inputkW0.02P
SB
Standby mode
kW0.00P
CK
Crankcase heater mode
Other items
m
3
/h180Rated airflow (air-water)VariableCapacity control
m
3
/hNominal heating medium flowdB44 / -L
WA
Sound power level, indoors/outdoors
m
3
/hBrine flow brine-water or water-water heat pumpskWh2,750Q
HE
Annual energy consumption
For heat pump combination heater
%91ƞ
wh
Water heating energy efficiencyLDeclared load profile for water heating
kWhQ
fuel
Daily fuel consumptionkWh5.11Q
elec
Daily energy consumption
GJAFCAnnual fuel consumptionkWh1,123AECAnnual energy consumption
NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – SwedenContact information
67Chapter 12 | Technical dataNIBE F730