General
Pipe installation must be carried out in accordance with
current norms and directives.
Internal support bushes should be fitted when a plastic
pipe or annealed copper pipe is used. The water heater
must be fitted with the requisite valves, such as a safety
valve, shut-off valve, non-return valve, and vacuum
valve. An overflow pipe must be routed from the safety
valve to a suitable drain. The size of the overflow pipe
must be the same as on the safety valve. Route the
overflow pipe from the safety valve enclosed along its
entire length and ensure that it is frost proof. The outlet
of the overflow pipe should be visible and clearly away
from any electrical components.
Dimensions and pipe connec-
tions
VPB 200/VPB 300
VPBS 300
XL8 XL13 XL4 XL3 XL9 XL14
XL5*
Connection
22mmXL3 Cold water Ø
22mmXL4 Hot water Ø
15mmXL5 Hot water circulation Ø
22mmXL8 Docking connection, flow line Ø
22mmXL9 Docking connection, return line Ø
22mmXL13 Solar flow line Ø
22mmXL14 Solar return line Ø
(*Not VPB/VPBS Cu)
9Chapter 4 | Pipe connectionsVPB/VPBS
4 Pipe connections