Service actions
Safety valve
The water heater's safety valve sometimes releases a
little water after hot water usage. This is because the
cold water, which enters the water heater to replace
the hot water, expands when heated causing the
pressure to rise and the safety valve to open.
The function of the safety valve must be checked regu-
larly. Perform checks as follows:
1.
Open the valve by turning the knob anti-clockwise
carefully.
2.
Check that water flows through the valve.
3.
Close the valve by releasing it. If it does not close
automatically when released, turn it anti-clockwise
slightly.
Emptying
The water heater is emptied through the siphon (with
hose) in the cold water connection (XL3).
Drain the coil section through the siphon (with hose)
on the docking connection, return to heat pump (XL9).
Drain the solar coil through the siphon (with hose) on
the connection, return to solar heating system (XL14).
LEK
XL3 XL9
VPB 200/VPB 300
LEK
XL3 XL9 XL14
VPBS 300
17Chapter 7 | ServiceVPB/VPBS