procedure terminates, the memorisation will occupy a single memory location and the command associated
with each key will depend on the “List of commands” present on the automation’s control unit.
PROCEDURE 1 - Mode 1 memorisation
01. On the receiver: hold down key A and wait for the green LED
B to light up. Subsequently, release key A.
1
2
1
2
02. On the transmitter being memorised:
If the transmitter is a one-way device:
(within 10 seconds) on the transmitter: hold down any key and
release it once LED B (on the receiver) emits the 1
st
of 3 green
flashes (=memorisation completed correctly). (*1)
If the transmitter is a two-way device:
(within 10 seconds) on the transmitter: press and immediately
release any key; LED B (on the receiver) will flash green 3 times
(=memorisation completed correctly). (*1)
(*1) Note - If there are other transmitters to be memorised, repeat step 02 within the next 15 seconds
after the first 10. The procedure will terminate automatically once this time elapses.
3.2 - Memorisation in “Mode 2”
While Procedure 2 is being carried out, the receiver memorises a single key among those present on the trans-
mitter, associating it with the receiver output chosen by the installer. To memorise further keys, repeat the pro-
cedure from the beginning for each key to be memorised. Once the procedure terminates, the memorisation
will occupy a single memory location and the command associated with the memorised key will be that chosen