Summary
Preface P. 6
Chapter 2 P. 17
Technical data
Chapter 5 P. 76
Reception, storage
and installation
Chapter 4 P. 54
General information
Chapter 3 P. 47
Application notes
Chapter 6 P. 115
Options
Chapter 7 P. 129
Preventive maintenance
Chapter 1 P. 15
Overview
and installation diagram
Answer Drives 1000
27
2/3
2
PROTECTIONS
Overcurrent
Under voltage
Motor overload
Ground fault
cl. 2: 150% X60s every 10 min
CONNECTIONS TO THE MOTOR
Over voltage
Drive overtemperature
Engine overspeed
Overload:
cl.1: 110% X60s every 10 min
Serial tear
Three-phase voltage: from 0 to the power supply network
voltage
Switching frequency: 1.5-8 kHz
Frequency precision (V/Hz): 0.1% (analogue control)
Speed resolution: 1:5000 (Sensorless)
Output frequency: 0.1-200Hz
Frequency resolution (V/Hz):
0.1Hz
0.01% (digital control)
Static accuracy rate: 0,01% (Sensorless)
2.7 GENERAL DATA
Watchdog
External Fault
Response time of the torque
controller
5ms (Sensorless)