Preface P. 6
Chapter 2 P. 17
Technical data
Chapter 5 P. 76
Reception, storage
and installation
Chapter 4 P. 54
General information
Chapter 3 P. 47
Application notes
Chapter 6 P. 115
Options
Chapter 7 P. 129
Preventive maintenance
Chapter 1 P. 15
Overview
and installation diagram
Answer Drives 1000
17
2
2 TECHNICAL DATA
2.1 NOTES ON CONTROL METHODS
Scalar control V/f
Voltage-frequency adjustment with constant or variable ratio
Voltage boost
Open loop adjustment
Speed adjustment range: 1:15
Speed resolution: 0.1Hz
Sliding compensation
Output current control
Scalar control with Sensorless performance: Vector V/f
Voltage-frequency adjustment with constant or variable ratio,
with torque current control
Excellent static and dynamic performance
Open loop adjustment (closed simulated)
Speed adjustment range: 1:15
Speed resolution: 0.1 Hz
Static accuracy of typical speed: 0,4 x sliding frequency %
Output current control
Torque control response: < 10 ms
2 TECHNICAL DATA - 2.1
The Drive AD1000 can control the motor in two different modes:
c. Scalar V/f: for simple applications and no speed feedback
d. Sensorless Vector V/f: for applications that require greater dynamic
performance and accuracy and no speed feedback.