4.3.2 REQUIREMENTS IN CASE OF ELECTRICAL INSTALLATION
The AD1000 contains components sensitive to electrostatic discharge;
these components may be damaged if handled improperly. During
maintenance or replacement of the electronic boards, it is necessary to
take adequate protection against electrostatic discharge (ESD):
• Use a maintenance kit for electrostatic charges.
• Wear properly grounded static straps.
• Handle the boards by the edges.
• Boards must not come into contact with highly insulating materials
such as plastic sheets, insulating surfaces, parts of synthetic fabrics.
• The boards will be placed on conductive surfaces.
• The boards must be packaged in conductive sheets before shipment.
• The IGBT modules are sensitive to electrostatic charges.
Handle with care to avoid damage. Do not leave open the gate-emitter
control terminals. Short circuit these pins with anti-static sponge or with
a metal jumper terminal when they are not connected to the control
board. Remove the short circuit, when reconnecting the control board.
Do not touch the pins of the device with your fingers.