11
Normal display
The main display shows “0:00”.
Press the ENT key and start
setting parameters. (The main
display shows the current
set numerical value of each
parameter.)
Every time you press the
key, the display switches to the
next parameter.
Press the SET key.
The display goes to mode 2
(elapsed timecounter mode).
No. Setting item Description Input range Default setting
F1 High set point 1 value
Sets the high set point 1 value (Hour:Minute:Second display system) 0:00:00 - 9:59:59 Second display system
0:00Sets the high set point 1 value (Second display system) 0:00 - 999:99
F2 Low set point 1 value
Sets the low set point 1 value (Hour:Minute:Second display system) 0:00:00 - 9:59:59 Second display
0:00Sets the low set point 1 value (Second display system) 0:00 - 999:99
F3 High set point 2 value
Sets the high set point 2 value (Hour:Minute:Second display system) 0:00:00 - 9:59:59 Second display
0:00Sets the high set point 2 value (Second display system) 0:00 - 999:99
F4 Low set point 2 value
Sets the low set point 2 value (Hour:Minute:Second display system) 0:00:00 - 9:59:59 Second display
0:00Sets the low set point 2 value (Second display system) 0:00 - 999:99
F5
Hysteresis of the high
and low set point 1 values
Sets the hysteresis of the high and low set point 1 values 0 - 99 0
F6
Judgment output timer
at startup
Sets the time when the comparator judgment is output at startup 0 - 99 sec. 0 sec.
F7
Minimum revolution
speed
Sets the revolution speed to be displayed as zero 000000 - 999999 0
F8
Frequency of the moving
average
Used when variation of the revolution speed is large and a stable
display cannot be attained
0(disabled)/1(3 times)/2(10 times) 0(disabled)
F9 Pre-arithmetic function Promptly performs the deceleration display when the signal is lost 0(disabled)/1(enabled) 0(disabled)
* For the description of functions, refer to page 21.
Note) When the input signal stops in the elapsed timecounter mode, the display will overow after the specied time set with the auto zero function.
The overow display “-.-.-.-.-.-. does not mean there is a malfunction. When the input signal is within the display range, the display returns to normal.
0: 0 0
0 2 - P 0 1
--
0 0 6 0
--
6. 0
-
1 2 0 0
-
0: 0 1: 4 7
--
0 0 0 1
-
0 1 0 0 0
-
0 1 0: 0 0
-
2. 0
-
-
1. 0
-
--
0 1 0. 0
0: 0 0: 0 0
-
1 0
- -
3 0
-
Press and hold the SHIFT +
PARA keys for 5 seconds or
more to switch to the param
-
eter setting mode.
0.2 0.5 1.0 2.0 5.0
60●●●30●●●15●●●10
10 30 100 0.02
• Function setting item in mode 2 (elapsed timecounter mode)
(3) Function (For the setting method, refer to pages 16 and 17.)
●Start setting according to the setting example on the previous page.
Parameter 1 setting
To the parameter settings
Parameter 2 setting
Parameter 3 setting
Parameter 4 setting
Parameter 5 setting
Parameter 6 setting
Finish setting
Use the
key to move to another digit
Use the key to change the numerical value
to “60”.
Use the ENT key to nish setting.
Use the key to move to another digit
Use the key to change the numerical value
to “1200”.
Use the ENT key to nish setting.
*If you enter a value outside the setting range, all the input values will blink, which indicates the setting is disabled.
●When this occurs, you cannot switch to other displays until you enter a value within the setting range.
Every time you press the ● key, the
display switches as below.
Select "1.0" and use the ENT key to
nish setting.
Select "30" and use the ENT key to
nish setting.
Every time you press the ● key, the
display switches as below.
Use the key to move to another digit
Use the key to change the numerical value
to “0:01:47”.
Use the ENT key to nish setting.
To switch the Hour:Minute:Second display
(0:10:00) and Second display (10:00), use the
key with ":" selected by the key.
Use the key to move to another digit
Use the key to change the numerical value
to “6.0”.
Use the ENT key to nish setting.
(Use the
key to select the decimal point, and
use the key to change its position.)
s
t
s
t
s
t
s
t
s
t
s
t
www.calcert.com sales@calcert.com1.888.610.7664
0
5
10
15
20
25
30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nidec DT-501X and is the answer not in the manual?

Nidec DT-501X Specifications

General IconGeneral
BrandNidec
ModelDT-501X
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals