26 Unidrive M702 / HS72 Control Getting Started Guide
Issue Number: 4
4.14 Transferring data
Data transfer, erasing and protecting the information is performed by entering a code in Pr mm.000
and then resetting the drive as shown in Table 4-4.
Table 4-4 SMARTCARD and SD card codes
Code Operation SMARTCARD SD card
2001
Transfer the drive parameters to parameter file 001 and sets the
block as bootable. This will include the parameters from attached
option modules.
99
4yyy
Transfer the drive parameters to parameter file yyy. This will include
the parameters from attached option modules.
99
5yyy Transfer the onboard user program to onboard user program file yyy.
99
6yyy
Load the drive parameters from parameter file yyy or the onboard
user program from onboard user program file yyy.
99
7yyy Erase file yyy.
99
8yyy
Compare the data in the drive with file yyy. If the files are the same
then Pr mm.000 (mm.000) is simply reset to 0 when the compare is
complete. If the files are different a ‘Card Compare’ trip is initiated.
All other NV media card trips also apply.
99
9555 Clear the warning suppression flag
99
9666 Set the warning suppression flag
99
9777 Clear the read-only flag
99
9888 Set the read-only flag
99
9999 Erase and format the NV media card
9