CIRCUIT BREAKER TRIPPING
Circuit breakers protect electrical circuits and motors from damage due to overload conditions. If a circuit breaker trips, turn the Master Key Switch
(A) OFF and remove the key. Then try to determine the cause. Once the problem has been corrected, reset the circuit breaker by pushing the
button in. If the button does not stay in, wait 5 minutes and try again. If the circuit breaker trips repeatedly, call Nil sk-Advance for service.
Possible cause for the Control Circuit Circuit Breaker (18) tripping may be:
1 Short circuit in the wiring - have your Nil sk-Advance Service Technician service the machine
Possible causes for the Wheel Drive Circuit Breaker (17) tripping may be:
1 Debris wrapped around the drive wheel axle.
2 Worn out drive motor bearings.
3 Continuous use on ramps.
POOR WATER PICKUP
1 Recovery tank full, vacuum shut-off switch activated or dirty
2 Blocked vacuum system (squeegee and hoses)
3 Disconnected or damaged vacuum hoses
4 Incorrectly adjusted squeegee
5 Recovery tank cover gasket damaged
SQUEEGEE STREAKS
1 Debris under the squeegee blade
2 Worn, nicked or torn squeegee blade
3 Incorrectly adjusted squeegee
SWIRL MARKS
1 Running the machine with dry brushes or pads (no cleaning solution)
2 Incorrect brushes or pads for the application
3 Debris caught in brushes (or pads)
NO SOLUTION FLOW
1 Solution Shut-Off Valve (13) closed.
2 Solution Filter (11) clogged.
3 Solution pump bad.
SCRUB DECK RAISES WHILE SCRUBBING (CYLINDRICAL)
1 Debris caught between brushes and brush housing.
2 Bad brush Motor bearing.
NO DETERGENT FLOW (AXP/EDS)
1 Empty detergent cartridge.
2 Plugged or kinked detergent ow line.
3 Detergent pump wiring disconnected or wired incorrectly.
4 Dry seal cap on detergent cartridge not sealed.
revised 5/05

Table of Contents

Other manuals for Nilfisk-Advance Convertamatic 24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance Convertamatic 24 and is the answer not in the manual?

Nilfisk-Advance Convertamatic 24 Specifications

General IconGeneral
BrandNilfisk-Advance
ModelConvertamatic 24
CategoryScrubber
LanguageEnglish

Related product manuals