Configure an E-240W-A indoor ONT
100
7368 ISAM ONT E-240W-A Product Guide
3FE-46974-AAAA-TCZZA Issue: 01
Table 27 describes the fields in the US Classifier window.
Table 27 US Classifier parameters
Field Description
Policy parameters
Tunnel Type The tunnel type is set to GRE and cannot be modified.
Tunnel Interface Choose a tunnel interface from the drop-down menu: No Tunnel, GRE
Tunnel, or LAN traffic.
VLAN ID Enter a VLAN ID (0-4094).
VLAN Tag This field is not configurable. The VLAN tag is set to 8100.
VLAN Priority Enter a VLAN priority level (0 to 7). A lower number indicates a higher
priority.
IP TOS/DSCP This field is not configurable. All tunnel packets are generated with a
default DSCP value (usually 0).
Classifier parameters
Interface Choose an interface from the drop-down menu, for example: None, LAN,
2.4G SSID, 5G SSID.
Source MAC Click to enter a source MAC.
Destination MAC Click to enter a destination MAC.
Source IP Click to enter a source IP.
Destination IP Click to enter a destination IP.
Source Port Click to enter a source port.
Destination Port Click to enter a destination port.
Protocol Click to enter a protocol.
Priority Choose a priority level from 1 to 8. The lower the number, the higher the
priority. No more than 1 classifier can be created with the same priority.
Classifier Rules parameters
Policy Choose a policy from the drop-down menu.
Classifier Choose a classifier from the drop-down menu.
Interface Choose an interface from the drop-down menu, for example: None, LAN,
2.4G SSID, 5G SSID.
Source MAC Enter a source MAC.
Destination MAC Enter a destination MAC.
Source IP Enter a source IP.
Destination IP Enter a destination IP.
Source Port Enter a source port.
Destination Port Enter a destination port.
IP Protocol type Enter a value between 0 and 254.
Release 06.00.00h | January 2019 | Edition 08