Table15
RRHModuleinputvoltagerange(Cont.)
Property
Value
Nominalinputvoltagerange -40.5VDCto-57.0VDC
Extendedinputvoltagerange -36.0VDCto-40.5VDC
-57.0VDCto-60.0VDC
g
Theminimumstartupvoltageis40.5VDC.
Iftheinputvoltageisbelow/beyondextendedlimits,unitmayshutdown.
RRH output power
Basictypicalconditions:
•
ambienttemperature23°C
•
noALDpowerfeedingincluded
•
noRETpowerfeedingincluded
Non-committedestimatedvaluespendingoffinalproductHWandSWoptimizationwith
+/-10%margin.ConsumptionfordedicatedWCDMA/LTEoperation(noMCPARF
sharing).
Table16
RRHpowerconsumption
Configuration
Number of TX
RF output
power per
sector
[W]
Est. power consumption [W]
at 48 VDC input in 23 °C
50% RF load
100% RF
load
RRH2x40W
850MHz
FHCA
2
40+40 260 350
20+20 200 240
RRH2x40W
900MHz
FHDA
2
40+40 305 344
20+20 192 233
RRH2x60W
900MHz
FHDB
2
60+60 335 458
40+40 266 351
20+20 189 232
RRH2x40W 2 40+40 303 397
Powerrequirementsandoutputpower FlexiMultiradioBTSRadioModuleandRemoteRadio
HeadDescription
50 DN0951745 Issue:05