12. Measure the power levels with a marker.
Take the first measurement from 250 us after the trigger, the second from 750 us, third on 1220 us and
so on in every 500 us until the table is filled.
Figure 66 High burst measurement
13. In the
High Burst
pane, click Calculate.
14. Check that the calculated values are within the limits specified in the following table:
Min Max
C0-high -0.5 5
C1-high -50 50
C2-high 400 900
C0-mid -0.7 0.7
C1-mid 0 50
C2-mid 400 900
C0-low -4 4
C1-low -400 440
C2-low -10000 15000
RM-91; RM-92
RF Troubleshooting and Manual Tuning Guide Nokia Customer Care
Issue 1 COMPANY CONFIDENTIAL Page 7 –53
Copyright © 2006 Nokia. All rights reserved.