9
Sensi 5
Crop on
Soil on
3.7 CHANGING THE SYSTEM SENSITIVITY
A sensitivity setting of 5 (default setting).
Toggle the "SETUP” switch to view the current Sensi setting.
While viewing this menu, toggle the " +/- " switch to adjust the
Sensi value.
Lower numbers reduce system sensitivity and improve stability.
Increasing the number will increase the response of the system (five is
the default setting).
If the Sensi setting is modified, the panel will return to the Normal
Operating screen after 3 seconds.
A lower Sensi setting may be required for stable control at the start
of operation (before sprayer is warmed up).
As the sprayer warms up increase the Sensi setting until the
performance reaches an optimum level.
Refer to the UC4+ Operators Manual for a discussion of performance
issues
3.8 CHANGING BETWEEN SOIL AND CROP MODE
System is in CROP mode
System is in SOIL mode
SOIL or CROP mode can be adjusted in both MANUAL and AUTO
modes.
To view the current setting, toggle the "SETUP (NO)" switch twice.
While viewing this menu, use the " +/- " switch to change between
SOIL and CROP mode.
Wait five seconds for the change to take effect on all sensors.
If the mode is modified the panel will return to the Normal Operating
screen after 3 seconds.