5 Parameter
BU 0200 en-3118 183
Pos: 45 9 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P4 00-P4 99/Par amet er P465 – Festfrequenz Feld [SK 1x0E, SK 2xxE, SK 2xxE-FD S] @ 2\mod_1346931809249_388.docx @ 42840 @ @ 1
P465 [-01]
...
[-15]
Fixed frequency field
(Fixed frequency / Frequency array)
-400.0 ... 400.0 Hz
{ [-01] = 5.0 }
{ [-02] = 10.0 }
{ [-03] = 20.0 }
{ [-04] = 35.0 }
{ [-05] = 50.0 }
{ [-06] = 70.0 }
{ [-07] = 100.0 }
{ [-08] = 0.0 }
{ [-09] = -5.0 }
{ [-10] = -10.0 }
{ [-11] = -20.0 }
{ [-12] = -35.0 }
{ [-13] = -50.0 }
{ [-14] = -70.0 }
{ [-15] = -100.0 }
In the array levels, up to 15 different fixed frequencies can be set, which in turn can be encoded
for the functions 50…54 in binary code for the digital inputs.
[-01] = Fixed frequency 1 / Array 1
[-02] = Fixed frequency 2 / Array 2
[-03] = Fixed frequency 3 / Array 3
[-04] = Fixed frequency 4 / Array 4
[-05] = Fixed frequency / Array 5
[-06] = Fixed frequency / Array 6
[-07] = Fixed frequency / Array 7
[-08] = Fixed frequency / Array 8
[-09] = Fixed frequency / Array 9
[-10] = Fixed frequency / Array 10
[-11] = Fixed frequency / Array 11
[-12] = Fixed frequency / Array 12
[-13] = Fixed frequency / Array 13
[-14] = Fixed frequency / Array 14
[-15] = Fixed frequency / Array 15
Pos: 46 0 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P 400-P4 99/P aramet er P466 – Mini malf requ enz Pr ozes sr egl er @ 0\mod_1328002464186_388.docx @ 10710 @ @ 1
P466 Min.freq. process cont.
(Minimum frequency process controller)
S P
0.0 ... 400.0 Hz
{ 0.0 }
With the aid of the minimum frequency process controller the control ratio can also be kept to a
minimum ratio, even with a master value of “zero”, in order to enable adjustment of the
compensator. More details can be found in P400 and (chapter 8.2).
Pos: 46 1 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P4 00-P4 99/Par amet er P475 – Ein-/ Ausschaltverz ögerung Digitalfunktion [SK 2xxE] @ 2\mod_1346931809920_388.docx @ 42864 @ @ 1
P475 [-01]
...
[-04]
delay on/off switch
(Digital function switch on/off delay)
S
-
sec
{ 0,000 }
Adjustable switch-on/off delay for the digital inputs and the digital functions of the analogue inputs.
Use as a switch-on filter or simple process control is possible.
[-01] = Digital input 1
[-02] = Digital input 2
[-03] = Digital input 3
[-04] = Digital input 4
Positive values = switch-on delayed
Negative values = switch-off delayed
Pos: 46 2 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uch ko mpakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1