EasyManuals Logo

Nord Drivesystems SK 700E Series User Manual

Nord Drivesystems SK 700E Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
1.2 USS - Modules
BU 0050 GB-3111 Subject to technical amendments 15
1.2.2.5 USS Customer Interface
(SK CU1-USS, Option)
In addition to data connections, the USS customer units are also
equipped with conventional digital inputs and outputs.
Via the existing relay contacts, a mechanical motor brake can be
controlled or readiness for operation can be communicated to a
higher level system.
The digital input has a 2.5V switching threshold for the evaluation
of the temperature sensor. The input can, however, also be used
for an emergency stop function.
Connector
Functions
Maximum cross-section
Parameter
X4.1
Output relay
1,5 mm
2
P434 ... P436
X4.2
Digital input
1,5 mm
2
P420
X4.3
Data cables
1,5 mm
2
P503 ... P548
NOTE: All control voltages are based on a common reference potential!
Potentials AGND /0V and GND /0V are internally linked in the device.
The maximum total current 5/15V is 300mA!
X4.1
X4.2
X4.3
01 REL1.1
02 REL1.2
41 VO +5V
40 GND /0V
73 RS485+
74 RS485-
21 DIG IN 1
42 VO +15V
Data cables:
RS485
(terminal 73-74, RS485 +/-)
Control signal: 2.5 ... 33V
Output relay:
Max. 2.0A
28V DC /230 V AC
Digital input 1 (P420)
Voltage supply: 15V
USS
USS termination resistor
not connected
connected
ON
OF
F