A 2-3
E 2000 Nordson Corporation
All rights reserved
41-3000
Issued 11/00
A2EN-02-[3-OVER]2
If the melter has the temperature setback and monitoring feature, the
temperature of all heated zones can be reduced during periods when
normal operation must be interrupted for several hours. When the
setback feature is activated, the controller reduces the temperature of all
zones below their operating temperature setpoints by the value selected
on the temperature setback control dial.
4130777A
1
2
3
4
5
6
7
8
9
10
Fig. A 2-2 Adhesive Flow Path of a Typical Gear Pump System
1. Typical motor
2. Tank
3. Gear pump
4. Pressure relief valve
5. Manifold
6. Filter
7. Gun
8. Hose
9. Drain valve
10. Pressure control valve
Standby Mode