Page #107 background imageLoading...
Page #107 background image
A
3-32
lnstallation
Programming
SYSTEM
SETTINGS Controls
(contd.)
Feature
No.
Feature
Description
Default
Setting
Optional
Settings
24
25
30&31
26
27
28
29
34
35
36
37
32
Auto-Energize
Pump
Auto-Energize
Heaters
Time With
Heaters On
Fault
Log
(most
recent)
Fault Log
(second
most
recent)
Fault Log
(third
most recent)
Auto Standby
Timeout
and
ln
Standby
Tlmeout
Auto-Energize
Pump
Temperature
Setting
Remote Pump
Enable/Remote
Heaters
On
Warning Log
(most
recent)
Warning
Log
(second
most
recent)
Warning Log
(third
most
recent)
Piston
pump
units only: Allows
you
to turn the
auto-energize
pump
feature on or off. lf
this
feature is
on,
the system turns the
pump
on automatically once the tank
reaches
the
preset
temperature
of
Feature No.
32. lf the
auto-energize
pump
feature is off,
you
must turn the
pump
on by
pressing
the PUMP key
until the PUMP light turns on.
Allows
you
to turn
the auto-energize heaters feature on or
off.
lf
the feature is on,
the system turns heaters on
automatically once the POWER
switch is turned on.
However, if
you
have
programmed
the system to turn
heaters
on and off automatically, using
the clock feature,
your
clock settings override
the auto-energize heaters
feature. lf
the auto-energize heaters
feature is off,
you
must
turn heaters
on manually, or allow any
clock settings
you
have
programmed
to turn heaters on or off.
Allows
you
to display the
total time
(in
hours) that the
heaters have
been running
to assist
with
servicing and
maintenance. Refer
lo Checking Run Time of Heatersin
lhe Maintenance section
of this manual.
Allows
you
to
display
the cause of the most recent
system
fault. Refer
to Checking the Warning
or
Fault Login
lhe
Operation
section for a list of fault codes.
Allows
you
to display the cause of
the second
most recent
system fault. Referto Checking
the Warning or Fault Login
lhe Operation section for
a
list
of fault codes.
Allows
you
to display the cause of the
third
most recent
system fault. Refer
to Checking
the
Warning or Fault Log in
lhe Operation
section
for
a list of fault codes.
These features
are available
only on units
with
an l/O
board. Refer to Seres 3000V lnput/Output Boardinlhe
Options seclion
of this manual for information on
customizing these features.
Piston
pump
units only: Allows
you
to determine
when
the
pump
automatically
starts if
you
are using the auto-energize
pump
feature
(Feature
No. 24). You can have the
pump
start either when
the system reaches the READY condition
or
when
the tank reaches
a temperature
you
have
specified.
(See
Note B.)
This feature
is available
only on units
with
an l/O board.
Refer to Series 3000V lnput/Output
Boardinlhe Options
section of this manual for information
on customizing this
feature.
Allows
you
to display the
cause of the most recent system
warning. Refer to Checking
the Warning or Fault Log in lhe
Operation
section for a list of warning
codes.
Allows
you
to display
the cause of the second most
recent
system
warning.
Refer to Checking
the
Warning
or
Fault
Log in the Operation
section
for
a list of warning codes.
Allows
you
to display the cause of
the third
most recent
system
warning.
Refer to Checking
the
Warning
or
Fault
Log in
the Operation section for a list of warning
codes.
(on)
1
1
(on)
See Note A
See Note A
See
Note A
See
Note A
0
(ready)
See Note A
See Note A
See
Note A
NOTE A:
B:
Features 26-29
and 35-37 are always on. There is no
default setting.
lf
you
enter a setting that is higher
than the tank setpoint,
the
pump
will start when
the tank
reaches its
setpoint.
0
(off)
1
(on)
none
none
none
none
0
(ready
condition) or
1-23211450
('c/'F)
none
none
none
0
1
(off)
(on)
A3EN-04-[3V-X-4XXVj-1
3
41
-3000v
lssued 5/00
@
2000 Nordson Corporation
All rights reserued

Table of Contents

Other manuals for Nordson 3500V Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson 3500V Series and is the answer not in the manual?

Nordson 3500V Series Specifications

General IconGeneral
BrandNordson
Model3500V Series
CategoryMelting Machines
LanguageEnglish

Related product manuals