Loading...
B 1-12
Hydraulics
Actuator
Removal
1.
Move the hydraulic shaft up or down until shifter fork
is centered
in
the
pump
mount.
2.
See
Figure
B 1-5. Remove the screws and washers
(1)
that secure
the actuator
(3);then
remove
the actuator.
NOTE:
Series 3100t4 34OOV and
3500Vunits also
have
a
pump
cover bracket
(2)
that must be removed.
3.
lnspect the
O-rings
(4)
in
the face of the air cylinder for damage.
Replace if
necessary.
2
3
4
1
4130831
Fig. B 1-5 Removing
the Actuator
1.
Screwandwasher
2. Pump
cover bracket
(Series
310014 3400V
and 3500Vunits only)
3. Actuator
4. O-ring
B1 EN-02-[3V-X-AGXX]-2