lnstallation
A 3-21
7.
Connect
the output
wires
to the
plug
for terminal
block
TB2
from the
ship-with
kit. Refer to
Table A 3-3.
Table A 3-3 Output
Contact Connections
8. Connect
the
plug
to
TB2. See Figure
A 3-12
for the
location
otTB2.
9.
Go to
the
next
procedure,
Connecting
ElectricalSeruice.
Output
Contact
as
Labeled
on Power
Board
Behavior
of
Contact
TB2
Positions
(see
Note
A)
Unit
Power Off
Unit
Power On
Warning
Contact
(System
Warning)
Fault Contact
(System
Fault)
Ready Contact
(System
Ready)
Open
Open
Open
Closed
(no
warning)
Closed
(no
fault)
Open
(unit
not ready)
Open
(warning
exists)
Open
(fault
exists)
Closed
(unit
ready)
1
,
2
3,4
5,6
NOTE
A: The output
contacts
are
not
polarity
sensitive.
lt does
not matter
which
wire is inserted
into a
position.