Installation
3-19
Part 1032059B
E 2003 Nordson Corporation
Manual 41-DURABLUE-MA-02
4. Use the right-display scroll keys to enter the set-point temperature
recommended by the manufacturer of the hot melt.
Refer to the technical data sheet provided by the manufacturer of the
hot melt to determine the optimal set-point temperature.
5. Press the Tank key.
Each component begins to heat or cool to the new global set-point
temperature and the melter returns to the automatic scan mode.
When all of the components reach the global set-point temperature, the
ready LED turns on (green).