Installation
3-28
Part 1024496_06
2014 Nordson Corporation
Operating Parameters (contd)
Table 3‐6 Operating Parameters
Parameter Name Range of Values Default Value
Standard
0
Enter Password 0 to 9999 4000
1
Total Hours with Heaters On
(noneditable)
0-999,999 0
2
Fault Log (noneditable) _‐F0 (empty)
3
Change History Log (noneditable) P‐_ (empty)
4
Ready Delay Time 0 to 60 minutes 0 minutes
5
Service Interval Time 0 to 8736 hours 500 hours
6
Service LED Heater Hours 0 to 9999hours 0
8
Automatic Pump On 0 (disabled) or 1(enabled) 1 (enabled)
9
Automatic Pump On Temperature 0 (disabled) or (1 to 230 C) 0 (disabled)
10
Enable or Disable Password 0 (disabled) or 1(enabled) 0 (disabled)
11
Create Password 0 to 9999 5000
14
External Communications Lock‐out 0 or 1 0 (disabled)
Temperature Control
20
Temperature Units (degrees C or F) C (degrees Celsius) or F
(degrees Fahrenheit)
C (degrees Celsius)
21
Over Temperature Delta 5 C (10 F) to 60C(110 F) 15 C (25 F)
22
Under Temperature Delta 5 C (10 F) to 60C(110 F) 25 C (50 F)
23
Standby Delta 25 C (50 F) to 190C (350 F) 50 C (100 F)
24
Automatic Standby Timeout 0 to 1440minutes 0 (disabled)
25
Automatic Heaters Off Time 0 to 1440minutes 0 (disabled)
26
Manual Standby Time 0 to 180 minutes 0 (disabled)
Input Setup
30
Standard Input 1
0-10, 15-16
10 (Automatic
Standby)
31
Standard Input 2 0-9, 15-16 1 (Standby on/off)
32
Standard Input 3 0-9, 15-16 2 (Heaters on/off)
33
Standard Input 4
0-9, 15-16
4 (Hose/gun 1
enable/disable)
34
Optional Input 5 0-9, 15-16 0 (disabled)
35
Optional Input 6 0-9, 15-16 0 (disabled)
36
Optional Input 7 0-9, 15-16 0 (disabled)
37
Optional Input 8 0-9, 15-16 0 (disabled)
38
Optional Input 9 0-9, 15-16 0 (disabled)
39
Optional Input 10 0-9, 15-16 0 (disabled)
Continued...