2. Technical Data
2.1 Functional data
Tuning Fully Automac with opon to enable Automac Frequency Selecon (AFS)
Self-tuning range 20 µH to 1500 µH
Sensivity Four steps adjustable on the DIP switches (High, Medium-High, Medium-Low, Low)
Opons available are 0.01% ΔL/L, 0.02% ΔL/L, 0.05% ΔL/L and 0.10% ΔL/L
ASB (Automatic Sensivity Boost) is selectable via the DIP switches
Frequency With AFS switched on the channel tunes automatically to one of five possible frequencies
There are four selectable frequency opons with AFS switched o
Operang frequency of 18 110 kHz (Determined by loop geometry and frequency seng)
Output Configuraon 2 output relays
User congurable for: Presence on detect
Pulse on detect
Pulse Output Duraon 150ms
Presence Method Permanent or Limited presence
Presence Time Innite when the unit is on Permanent Presence
Dependant on level of detect and environmental condions when on Limited Presence
Dri Compensaon Rate Approx. 1 %L/L per minute
Response Times Detect: 53.0 73.0ms
Undetect: 280.0 350.0ms
Subject to sensivity level, level of detect and speed of vehicle over the loop
Visual Indications 1 x Power / Status LED Red
2 x Channel Status LED Green
Reset Holding the reset buon for 3s iniates a retune
Surge protecon Loop isolaon transformer, gas discharge tubes, and Zener diode clamping on loop input.
Power Fail Innite memory retenon of detector state on power failure (provided certain criteria are
met refer to secon 4.5). This funcon can be turned on and o via the Reset push buon.