Details hazards related to electrical shock, fire, or explosion, emphasizing proper servicing and disconnection of power.
Outlines the installer's responsibility to know the product, follow safety guidelines, and instruct the customer on operation and maintenance.
Specifies required clearances around the appliance for positioning and servicing, referencing Table 1.
Reiterates critical safety warnings related to electrical hazards during installation and servicing.
Important notes on line voltage polarity and circuit breaker protection for the unit.
Step-by-step instructions for making the main power supply wire connections to the unit.
Emphasizes the necessity of an uninterrupted electrical ground for safety and proper operation.
Details for connecting the 24VAC thermostat, including mounting recommendations.
A checklist of essential items to verify before energizing the appliance, ensuring correct connections and grounding.
Steps to follow for safely starting up and commissioning the appliance after installation.
Illustration of the E7 motor control board, showing DIP switches, display codes, and connection terminals.
Checklist items verifying electrical connections, polarity, voltage, thermostat calibration, grounding, and anticipator settings.
| Efficiency Rating | Up to 80% AFUE |
|---|---|
| Efficiency | 80% AFUE |
| Type | Downflow |
| Heating Capacity | 40, 000 - 120, 000 BTU/h |
| Fuel Type | Natural Gas or Propane |
| Dimensions | Varies by model; refer to specification sheet |
| Model | E7ED DOWNFLOW |