33
Table 11
VENT TERMINAL
AIR SUPPLY INLET
AREA WHERE TERMINAL IS NOT PERMITTED

CLEARANCE LOCATION
CANADIAN INSTALLATIONS
A
US INSTALLATIONS
B

CONVENTIONAL VENT (1-PIPE)
FURNACES
DIRECT VENT
(2-PIPE) FURNACES
CONVENTIONAL VENT
(1-PIPE) FURNACES

Clearance above grade, veranda, porch, deck,

  

Clearance to window or door
that may be opened.






above opening








 Clearance to permanently closed window


above the terminal within a horizontal distance

terminal.
 
 Clearance to outside corner.
 Clearance to inside corner.


above meter/regulator assembly.

above the meter/regulator assembly
 Clearance to service regulator vent outlet. 


building or the combustion air inlet to any other
appliance.






above opening








 Clearance to mechanical air supply inlet. 





Clearance above paved sidewalk or driveway
located on public property.

c


Clearance under veranda, porch, deck, or
balcony.

d


c: A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
d: Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.


