Nortek FG7MQ - Horizontal & Vertical Venting Options Diagrams; Horizontal Venting Diagram; Vertical Venting Diagram

Nortek FG7MQ
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36


VERTICAL VENTING
(2-Pipe Shown)
Support System on
Vertical Rise
First Support as Close
to Furnace as Possible
Couplings with 2
Hose Clamps (Optional)
HORIZONTAL VENTING
(2-Pipe Shown)
FLUE PIPE
Coupling with 2 Hose
Clamps (Optional)
Straps or Other Suitable
Supports at minimum of 5 ft. Intervals
Upward Pitch - 1/4per foot
(Flue Pipe)
First support placed as close
to furnace connection as possible
Wall
Normal
Snow Level
COMBUSTION AIR
90° Elbow
(both ends)
Seal/Caulk
Around Pipes
at Building
90°
Elbow
7”
12”
Min.
90°
Elbow
90° Elbow
Support System on
Vertical Rise
COMBUSTION AIR
PVC Tee
FLUE PIPE
FLUE PIPE
COMBUSTION AIR
PVC Trap
PVC Tee
PVC Trap
PVC Tee
PVC Trap
Table 2

Table 2

Table 2
