6. Programming
To program the 232e keypad, you must first enter program mode by
pressing 99 # Master Code *. The default Master Code is 1234.
6.1 Programming Main Relay Time
Command/Action Keys to Enter/Details
Command 11,
Set Main Relay Time
11 # time # 0 # **
(Time can be from 1-255 seconds.)
Command 44.
Set Propped Door
Time
44 # time # 0 # **
Options:
time
ProppedDoorTime-roundeddownto
nearest 10’s of seconds; entered as 00, 10
through 990, defaults to 30 seconds; entering
atimeofzerodisablesthefunction
Command 45.
SetForcedDoorTime
Options:
time
Forced Door Time - rounded down to nearest
10’s of seconds; entered as 00, 10 through
990, defaults to 10 seconds; entering a time of
zero latches the virtual forced door that can
beclearedwithanyvalidPINorbyentering
program mode