To ensure your machine remains at its maximum efciency and prolong your battery life,
please follow the simple steps below:
Under normal daily usage:
Recharge batteries after each use regardless of machine operation time. (See page 40)
Showing location of Viewing panel for charging-light sequence (Fig.39).
Recharge the machine fully after its last use.
Do not leave the machine in a discharged state.
Under abnormal use; i.e. leaving the machine without charging
for a period of time - we advise that you follow these steps:
If the machine will be standing unused for a period of 30 days
or more, then batteries must be fully charged and battery fuses
removed using the Maxi fuse-puller provided, prior to this period.
Batteries should be recharged every three months.
Charge fully the day before you start using the machine again.
Battery Care
39
Signal (LED) Meaning
Red
LED on
First phase (constant current mode)
Yellow
LED on
Second phase (constant voltage mode)
Green
LED on
Third phase (constant voltage mode) charge completed
Red
LED
ashing
Charging System Error
Unsuitable battery or charging malfunction safety timer exceeded
Internal short circuit, disconnect from power supply, switch power supply,
OFF then ON, to restart the charging cycle
Yellow
LED
ashing
Battery not connected